Blog / Newsletter
Introduction
QR110 QR Code Scanner is FingerTec latest product that comes with a new verification method: QR Code along with the capabilities to scan RFID/MiFare access cards as well. As a slave reader, QR110 will need to be paired with FingerTec Ingressus controllers and master readers such as R3, R2, Q2i and etc before the whole system works.
Introduction
QR110 QR Code Scanner is FingerTec latest product that comes with a new verification method: QR Code along with the capabilities to scan RFID/MiFare access cards as well. As a slave reader, QR110 will need to be paired with FingerTec Ingressus controllers and master readers such as R3, R2, Q2i and etc before the whole system works.
QR110 is built with a 34-bit Wiegand communication. Even though FingerTec master devices comes with 34-bit and 26-bit Wiegand, by default all FingerTec Master Devices is set with 26-bit Wiegand Communication. Therefore, you need to change the Wiegand communication to 34-bit before you can connect the reader to QR110.
Please follow the steps below for QR110 installation:
Process:
1) Connect the wirings between QR110 and FingerTec Controller and Biometrics Devices
For Ingressus I,II, and IV, please connect the respective devices to the following QR110 ports (D1, D0, GND, VCC) as shown in the circuit diagram below:
For Master Readers (R2, R3, Kadex, m-Kadex, Q2i, Face ID 3), please connect the respective devices to the following QR110 ports (D1, D0, GND, VCC) as shown in the circuit diagram below:
2) Enable Wiegand 34-bit Format in FingerTec Device
(Note: All previous Wiegand 26-bit pairing will be overwritten once this step is carried out)
In R2 and Kadex, please go to Menu > Option > System Option > Wiegand Input Setting > FP device > Input Format = WG34 Without ID > Restart
*For R2 (FEM 500) that is paired with R2i, you will need to disable the pairing with R2i first as R2i is using Wiegand 26-bit and will not function on a 34-bit Wiegand Connection.
*For R2 that is paired with R2c, you can proceed with the step since R2c is connected by RS 485 and will not be interrupted by the change.
In R3 and Q2i, please go to Menu > Comm > Wiegand > Input Option > Define = 34 > Bit counts = 34 > Input = NO. > Restart
*QR110 is not compatible with Q2i (FEM 510)
*For R3 that is paired with R2c, you can proceed with the step since R2c is connected by RS 485 and will not be interrupted by the change.
In Face ID 3, please go to Menu > Comm > Wiegand Input > Wiegand Format = Wiegand 34 > Input = Card No. > Save > Restart.
In m-Kadex, this model does not come with an interface design. Therefore, a software tool is required to enable it into a Wiegand 34-bit format. Please download the software tool here and proceed to input the IP address of m-Kadex into the software tool. Once updated, the m-Kadex device will now accept 34-bit Wiegand Connection. (This method can also be applied to R2 and Kadex) Please refer to the screenshot below for more information:
In Ingressus I, II, and IV, the devices will automatically detect and configure its Wiegand Connection once connected to QR110. Therefore, removing the need for any manual setting.
After the configuration is done, the FingerTec devices will then be paired with QR110.
In Ingressus I, II, and IV, the devices will automatically detect and configure its Wiegand Connection once connected to QR110. Therefore, removing the need for any manual setting.
After the configuration is done, the FingerTec devices will then be paired with QR110.